If when you try to restore maintenance in an SMP/E environment, the task fails with error messages:


 GIM51702S ** THE RESTORE COMMAND WAS NOT PROCESSED BECAUSE NO RELATED ZONE WAS SPECIFIED IN THE ZONE DEFINITION ENTRY.
 GIM50801S ** ZONE zone_name WAS NOT USED BECAUSE IT IS NOT DEFINED BY A ZONEINDEX SUBENTRY IN THE GLOBAL ZONE.

The reason can be that the SMP/E environment is missing the distribution zone that is related to the affected target zone, or the related distribution zone does not exist.

Solution:

To resolve:

Use UCLIN to define the proper RELATED value in the zone definition entry. Then rerun the job.

For example:

Submit a batch job with a step similar to the following example to either add the missing distribution zone that is related to the affected target zone, or define the existing distribution zone:


 	SET 	
 	BOUNDARY(target_zone_name) . 	
 	UCLIN . 	
 	ADD TARGETZONE(target_zone_name) 	
 	RELATED(distribution_zone_name) . 	
 	ENDUCL.