Issue:
Affects Release version(s): 1.3

Error Message :
No message, however RestartPlus is not prompting after executing a restart.

When performing a restart of a z/OS job via Restart Plus, the above error may be experienced.

Investigation

1) Check whether the object HEADER.MVS.RESTART.PLUS exists both in Client 0 and in the executing Client (Client 100, for example).

2) If the objects exist, check whether they contain the solution script (it has been noticed to be absent when this does not work as expected). 
Environment:
OS Version: N/A
Cause:
Cause type:
Configuration
Root Cause: Potential configuration issue with the MVS Header object.
Resolution:
Check the HEADER objects for whether the following is contained within and add if necessary:
 
:IF SYS_ACT_RESTART = 'Y'
: BEGINREAD "Enter parameter(s) for UC4.RestartPlus"
: READ &Suppress,"Y,N","Suppress Run Time Module Actions","N"
: READ &START,"17","Startstep",&START
: READ &ENDE,"17","Endstep",&ENDE
: READ &CC,",0000-9999","Return Code for RUN TIME MODULE",&CC
: READ &GDGOPT,"Y,N","Perform standard GDG bias processing","Y"
: READ &STPCODE,,"Step Condition Code (EX: STEPname=rc or PROCstep.STEPname=rc)",&STPCODE
: READ &AJCLC,"Y,N","Allow JCL changes (Y/N)","N"
: ENDREAD


Fix Status: No Fix

Fix Version(s):
N/A
Additional Information:
Workaround :