Restart in PostProcess fails with U00007039 - still active

Document ID : KB000087398
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
Error Message :
U00007039 Object '' could not be restarted. Reference object '' (RunID '') is still active.

When trying to restart a run in Post Process with

:SET &RESTART_RC# = RESTART_UC_OBJECT(&$NAME#,LAST,,,&$QUEUE#)
 
the above error message is displayed.

Using "LAST" restarts the Last execution of the Object, this could be a task that is not restartable when there are multiple parallel starts.

This does not happen with tasks that are spread out or single executions, only with parallel executions.

 
Environment:
OS Version: N/A
Cause:
Cause type:
By design
Root Cause: Post Process is functioning as designed.
Resolution:
To restart the Task use &$RUNID# instead of LAST Keyword.

Fix Status: No Fix

Fix Version(s):
N/A
Additional Information:
Workaround :
N/A