REPORTCENTER NOT WORKING AFTER UPGRADE TO NM 12.2

Document ID : KB000126373
Last Modified Date : 07/02/2019
Show Technical Document Details
Issue:

Cust reported that the ReportCenter component was not working after
the upgrade of NetMaster from 12.1 to 12.2.

REPTEST command returned these messages:

WRST0000 ReportCenter Function Test on NMYYYYY (Dormant
Control Region)
WRST0003 No action taken -- NMYYYYY ReportCenter control
region functions
WRST0003 are not yet fully implemented.
WRST0098 ReportCenter Function Test completed with no
errors or warnings.

Note: NMYYYYY comes from the real region name.

Environment:
OS: z/OS (2.3).
Resolution:

Cust managed to fix this problem by adding:

WRHFS1=(path of library that ReportCenter runs from)

to member IIAPARMS for future rollouts.

-

The immediate fix was to create INI member in RUNSYSIN and set
$WR$HFS1 = &STR (path of library that ReportCenter runs
from) followed by a NetMaster region startup.

 

This knowledge document that this author published in Jan 2019
was helpful:

https://comm.support.ca.com/kb/wrinwi18-trying-to-generate-java-task-jcl/kb000124110

Additional Information:

Please review these NetMaster documentation pages for additional
WRHFS1 information:

https://docops.ca.com/ca-netmaster-shared-content-library/12-2/en/reportcenter/migration-considerations/reportcenter-java-task


https://docops.ca.com/ca-netmaster-shared-content-library/12-2/en/reportcenter/running-the-reportcenter-java-task/start-the-reportcenter-control-region