Receiving Error Message 'TSS8007E ACCESSOR ID UNKNOWN' When Running TSSUTIL.

Document ID : KB000054164
Last Modified Date : 14/02/2018
Show Technical Document Details

Question:

 

When running TSSUTIL on system X using the CA Top Secret Audit Tracking File as input from system Y, audit entries for acids not defined to CA Top Secret on system X, the following message is being issued:

'TSS8007E ACCESSOR ID UNKNOWN'.

The acid is defined to CA Top Secret on system Y,

Example TSSUTIL input statement:

REPORT ACID(Unknown_Locally) EVENT(ALL) END

The same job runs fine on system Y with no TSS8007E messages.

 

Answer:

 

When specifying a TSSUTIL input parameter like DEPT or ACID, the DEPT or ACID will be verified to see if it exists on the system TSSUTIL is running report on.

If it does not exist, the TSS8007E will be received. If you want to report only on that acid, TSSUTIL must run on the system where that acid is defined.

This is working as designed.

The following will work on either, since not DEPT or ACID is specified:

REPORT EVENT(ALL) END

 

Additional Information: 

 

Please refer to the CA Top Secret Report And Tracking Guide for more details about the TSSUTIL program for CA Top Secret r15.0

For CA Top Secret r16.0 go to docops.ca.com site; signon; choose your product "CA Top Secret for z/OS - 16.0"; click on "Reporting" link; click on
      "TSSUTIL Utility" link for more details about the TSSUTIL utility.