Received CAS9180E - CPU XYZ REQUIRES A LMP KEY TO RUN PROD (BX) on bringing up new release of Endevor

Document ID : KB000017709
Last Modified Date : 14/02/2018
Show Technical Document Details

Description:

Install new release of Endevor and first time one goes to execute it message CAS9180E - CPU XYZ REQUIRES A LMP KEY TO RUN PROD (BX) is issued.

Solution:

Customers have installed v16 and on bringing v16 for the first received the following message:


CAS9180E - CPU XYZ REQUIRES A LMP KEY TO RUN PROD (BX) 

Product BX represents the Endevor feature called QUICK -EDIT which is an optional feature in Endevor. Prior to v16 the default value set in the EDITELM field in the C1DEFLTS table has 'N' , but with v16 it has been changed to 'Y' for the Best Practice Implementation as describe in the Endevor Scenario Guide.

If you are not using Quick Edit you must go in the CSIQSRC library member C1DEFLTS and change the following :


EDITELM=Y,               EDIT ELEMENT DIALOG OPTION          
To 
EDITELM=N,               EDIT ELEMENT DIALOG OPTION

And reassemble and link the module.