Receive error 204 loading new Datacom panels.

Document ID : KB000007464
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

When doing a SELREST on ADRPNL library i am getting error 0204.

This was happening when updating ADRPNL with new signon/signoff panels for 15.1.

Environment:
z/os 2.1, CA IPC 15.1 and CA Datacom/DB 15.1
Cause:

Error 0204 may happen: 

-When the VLS is not large enough.

-When a VLS FORMAT (prior the RESTORE) was not done.

-When there is prior error(JCL) in previous steps. 

-When the VLSUTIL  data set name is incorrect or corrupted.

 

204 I-O ERROR LIBRARY CONTROL BLOCK. BLOCK NBR IS nnnnn. RUN CANCELLED. ERROR CODE IS 204 

Explanation: (This abend was issued from VLSUTIL, the VLS Batch Utility under MVS, VSE, or CMS.) 

An attempt to read a block from a library file produced a read error. This error occurs for functions other than a file format. 

 

User Response: Resubmit the job. If this abend recurs, ask your Site Administrator to format and restore the library from a backup file. 

 

Resolution:

If nothing found then using the latest backup available:

Ask your Site Administrator to Format and Restore the library from a backup file. 

Additional Information:

See CA IPC 14.0 Message Reference Guide in section: ABEND CODE.

or

https://docops.ca.com/display/CADTS/Messages if CA Datacom/DB 15.0