Reason for message LAE0005E Unable to open LADXTRCT, LADXCNTL or LADREPT DCB running Quiet Point Analysis

Document ID : KB000012985
Last Modified Date : 14/02/2018
Show Technical Document Details
Question:

Did you know what to check when message LAE0005E Unable to open LADXTRCT, LADXCNTL or LADREPT DCB occur when running CA Log Analyzer Quiet Point Analysis Report?

Answer:

You need to check at the SDSF output if the allocation for the report was generated:

.ALLOC FI(LADREPT) +

BLKSIZE(7448) LRECL(137) RECFM(VB) +

SYSOUT(*)

RETCODE = 0

If the allocation for the report is not generated go to the Report File Specification and set the Allocation Parameters. Therefore please check if New Allocation ==> y is set at panel LAOS4  Process Log - Output Specifications:

REPORT FILE SPECIFICATIONS

Destination ==> S ( D - Dataset, S - Sysout, T - Terminal

Dataset Name ==>

Disposition ==> NEW ( SHR , OLD , NEW , RPL )

New Allocation ==> y ( Y - Specify allocation info, N - Use

Followed at panel LAALLOC Allocate File checking the ALLOCATION PARAMETERS

Volume Serial ==> ( Blank for authorized default )

Space Units ==> CYLINDER ( BLKS, TRKS or CYLS )

Primary Quantity ==> 20 ( In above units )

Secondary Quantity ==> 10 ( In above units )

Record Format ==> VBA

Record Length ==> 137

Block Size ==> 7448

Generic Unit ==> SYSDA ( Unit name for NON-SMS dataset)

Model DSCB (GDG) ==>