Ran CAIRIM to activate CA InterTest Bacth but I am getting following error: CAPE010E UNABLE TO LOCATE RUNTIME MODULES. INITIALIZATION INCOMPLETE. CAS9140E - Init error: CAINTERTESTBATCH Ver VHA0, Init routine RC=000C How can I correct this error?

Document ID : KB000046940
Last Modified Date : 14/02/2018
Show Technical Document Details

Question:

I reassemble HLQ.CAVHJCL(CAVHCONF) to set PINT=(INTBAT,SYMBAT,INTCICS) but when I ran CAIRIM to activate CA InterTest Bacth but I am getting following error:

CAPE010E UNABLE TO LOCATE RUNTIME MODULES. INITIALIZATION INCOMPLETE.
CAS9140E - Init error: CAINTERTESTBATCH Ver VHA0, Init routine RC=000C 

How can I correct this error?

 

Answer:

Due to assemble CAVHCONF with NOOBJECT compile option cause the problem.
Since CAVHCONF's PINT=(INTBAT,SYMBAT,INTCICS) does not activate CA SymDump Batch, CAIRIM should not looking for the runtime start up.
After reassemble the CAVHCONF with OBJECT compile option, CAIRIM start up correctly.

 

Additional Information: 

Reference CA InterTest and SymDump r10 Configuring documentation. CAIRIM to activate product.