PWP logs contain messages like: “******** UC_Send: send_to=*systemname#WPnnn”

Document ID : KB000087143
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
Error Message :
******** UC_Send: send_to=*systemname#WPnnn

Messages without the U- number appear in the Primary Work Process (PWP) logs several times a day.

Example:

20170127/132202.469 - ******** UC_Send: send_to=*WO12#WP003
20170127/132202.560 - ******** UC_Send: send_to=*WO12#WP005
20170127/132202.584 - ******** UC_Send: send_to=*WO12#WP006
20170127/132202.607 - ******** UC_Send: send_to=*WO12#WP008

 
Note: “WO12” in this example is the system name of the Automation Engine.
 
It occurs randomly (a few times a day), but it can not be reproduced on demand.

There is no known impact to the AE system, so these messages can safely be ignored.
 
Environment:
OS Version: N/A
Cause:
Cause type:
Defect
Root Cause: Debug message was issued without debug / trace mode switched on.
Resolution:
These messages are no longer being written to the PWP log file in the fix versions.

Update to a fix version listed below or a newer version if available.
 

Fix Status: Released

Fix Version(s):
Component(s): AE Server and Initialdata

Automation Engine 12.1.0 - Available
Automation Engine 12.0.3 - Available
Automation Engine 11.2.5 - Available
Additional Information:
Workaround :
N/A