PT743E module is not an APF authorized library module.

Document ID : KB000051140
Last Modified Date : 14/02/2018
Show Technical Document Details

Description:

In RC/Secure, when performing a recover dropped object security on a large amount of objects and then submitting on-line, the following error occurred:

*** PT743E: Module is NOT an APF Authorized Library Module ***  
*** A unrecoverable processing error has occurred. ***  

Solution:

Ensure the steps defined under the Operational Considerations chapter in the Implementation Guide for APF authorization are followed.

Also, check the bottom of the online report for the following error:

*** RS533 GETMAINED AREA EXAHUSTED ***  

The RS533 condition can cause the PT743E error. To resolve the RS533 GETMAIN problem (in turn resolving the PT743E condition) it is recommended to either submit the job in batch or if submitting online, to make the recover dropped object security a smaller set.