Promptset error in AWI

Document ID : KB000084651
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
A Prompt-Set in Java GUI is created and a Time-field is added. Data Reference UC_DATATYPE_TIME is selected automatically. A Default Time is set and the newly created Prompt-Set in AWI is opened:
 
0EM0N000001hlPx.png

As can be seen, the Data Reference is displayed wrongly (UC_CALENDAR_PERIOD).

When the Prompt-Set is created in the in AW, the error also appears. A Time/Date field is added and Time is selected for Type. Data Reference UC_DATATYPE_TIME is selected automatically. Set a Default Time:

 
0EM0N000001hlQ2.png

Save and close the Prompt-Set. Now open it again in AWI:
 
0EM0N000001hlQ7.png

Again, the Data Reference is displayed wrongly (UC_CALENDAR_PERIOD). If changed to UC_DATATYPE_TIME now, it will remain correctly.

The above has no influence on Objects using the Prompt-Set. They run normally. In the Java GUI, the Prompt-Set is always displayed correctly.
Resolution:
Update to a fix version listed below or a newer version if available.
  • Automic Web Interface 12.2.0
  • Automic Web Interface 12.1.1
  • Automic Web Interface 12.0.5