Processing for PTF RO95060

Document ID : KB000116839
Last Modified Date : 03/10/2018
Show Technical Document Details
Question:
HOLDDATA for RO95060 indicates that DDUTILITY needs to be submitted to report on the DATABASE and AREA occurrences named "UNIVERSAL".
DDUTILITY can be run with the CA-Datacom task up. Once/If any occurrences are found -

Can the corresponding DDUPDATE be run - or - must the CA-Datacom task be down?? 
Environment:
Z/os, CA Datacom/AD 15.0
Answer:
If you are CA Datacom/AD 15.0 then you don't have to go through the HOLDDATA - Its is not needed for AD sites.

If you are CA Datacom/DB 15.0 then DDUPDATE step2 is executed with MUF up.
Additional Information:
That APAR is to correct any previous DataDictionary error for  CA Datacom/DB sites.

Data Dictionary for CA Datacom/AD 15.0 is installed NEW  during upgrade so there is no previous error to correct.