Issue:

I am working on a PoC for SYSVIEW at Swiss Re in Zurich, and we have hit a problem with the configuration of GSSA.

SCM0102I Monitoring entries built via parmlib definitions: 0 

SCM0103W No monitoring entries created. System Condition Monitor will terminat

Environment:
SYsview and GSSA configuration
Cause:

SCM member was located in sysview.user.parmlib 

Resolution:

Move the SCM member to the SITE PARMLIB or INTO the installation SYSVIEW PARMLIB  

Additional Information:

See the dcoumentation