Preview in SQl SEC VARA without connection object causes forced traces

Document ID : KB000084402
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
Error Message :
U00015006 System forced memory trace dump.

Clicking on Preview in a SQL Vara without a Connection specified (see screenshot below) causes the system to write force traces.

0EM0N000001hlPs.png

After that, further previews and working with the VARA is no longer possible.

Logging out of the AWI and in again solves the situation.
Environment:
OS Version: N/A
Cause:
Cause type:
Defect
Root Cause: A PREVIEW of a variable with type SEC_SQL results in a forced trace if no connection is set. Error message is: U00005118 Program error: Database access via key 'EH_AH_Idnr' with value 0 in module 'UCDVAR_R'.
Resolution:
Update to a fix version listed below or a newer version if available.

Fix Status: In Progress

Fix Version(s):
Component(s): AE Server and Initialdata

Automation Engine 12.0.4 - Available
Automation Engine 11.2.8 - Planned release date: 2018-06-05
Additional Information:
Workaround :
N/A