PQC0032W UNABLE TO CONVERT TO FULL IMAGE COPY - PQC0192E INTERNAL RC 08 AT LOCATION 0120

Document ID : KB000045373
Last Modified Date : 14/02/2018
Show Technical Document Details

 

PROBLEM:

Running CA Quick Copy DB2 V10 NFM, incremental copy fails to convert to a full image copy with:

PQC0032W UNABLE TO CONVERT TO FULL IMAGE COPY - 

PQC0192E INTERNAL RC 08 AT LOCATION 0120  

 

CAUSE

FULL-AUTO Keyword—Convert an Incremental Copy to a Full Copy 

A potential data integrity problem arises when you take an incremental image copy 
after a load or reorg. If you use such an incremental copy for a recovery—with the 
corresponding full image copy and any other incremental copies—the log records are applied 
only after the latest incremental copy, beginning with the RBA. 


Per IBM Documentation for COPY utility for FULL NO: 
Incremental image copies are not allowed in the following situations:

After a successful LOAD or REORG operation, unless an inline copy was made during the LOAD or REORG job. 

 

RESOLUTION:

To correct this problem, simply take a full image Copy (MODIFY BITS YES)  after your Load or Reorg.