PPADB2 Post-Install job ssid0775 LOADRULS step fails

Document ID : KB000095425
Last Modified Date : 10/05/2018
Show Technical Document Details
Issue:
The LOADRULS step in the PPA Post-Install ssid0775 job fails with RC=08.
Cause:
Dataset contention for the SYSDISC, SYSERR, SYSMAP, allocations occurred between the two table loads due to the same dataset names being used for both tables.
Resolution:
This specific error condition caused by dataset contention on the LOADRULS step can be corrected by changing the dataset names associated with the file allocations for SYSDISC, SYSERR and SYSMAP to be unique between the two LOAD table sections.

Example:
.ALLOC FI(SYSDISC) DA('PROD.PPA.SYSDISC')+ 
 MOD CATALOG UNIT(SYSDA) SPACE(10,10) CYL RLSE 
.ALLOC FI(SYSERR) DA('PROD.PPA.SYSERR')+ 
MOD CATALOG UNIT(SYSDA) SPACE(10,10) CYL RLSE 
.ALLOC FI(SYSMAP) DA('PROD.PPA.SYSMAP')+ 
MOD CATALOG UNIT(SYSDA) SPACE(10,10) CYL RLSE 
...
LOAD DATA.....INTO TABLE PTI.PTPA_ES_RU2RE_1200
********************************************************************* 
.ALLOC FI(SYSDISC) DA('PROD.PPA2.SYSDISC')+ 
MOD CATALOG UNIT(SYSDA) SPACE(10,10) CYL RLSE 
.ALLOC FI(SYSERR) DA('PROD.PPA2.SYSERR')+ 
MOD CATALOG UNIT(SYSDA) SPACE(10,10) CYL RLSE 
.ALLOC FI(SYSMAP) DA('PROD.PPA2.SYSMAP')+
MOD CATALOG UNIT(SYSDA) SPACE(10,10) CYL RLSE 
....
LOAD DATA ...INTO TABLE PTI.PTPA_ES_RULES_1200