PIM 12.8 SP1: specialpgm problem on T5C1153

Document ID : KB000122892
Last Modified Date : 12/12/2018
Show Technical Document Details
Issue:
Specialpgm is not effective after applying T5C1153.
Before applying T5C1153, there was specialpgm for the program and no access log from the program was not recorded in audit log.
However, the access logs from the program started to be recorded after stopping PIM and applying T5C1153 and starting PIM.
And then, specialpgm became effective and the access logs from the program stopped to be recorded after restarting the program.
The access logs from the program are recorded again after restarting PIM.
This can be avoided by reverting T5C1153.
 
Environment:
PIM 12.8 SP1 / HP-UX
T5C1153 applied
 
Cause:
It is a side effect from other fix that contains in T5C1153.
Resolution:
This is fixed by testfix T5C1156.
Additional Information:
Please contact CA Support for testfix.