Issue:
Error Message :
U02007018 'DOWNbea.jolt.ServiceException: Invalid Session'

The PeopleSoft agent is shipped with a wrong entry in the ini file:
 
domain_Connection_Pwd= instead of DOMAIN_CONNECTION_PWD=

This leads to the error message described above.
Environment:
OS Version: N/A
Cause:
Cause type:
Defect
Root Cause: Peoplesoft agent ini file: Parameter domain_Connection_Pwd= should be DOMAIN_CONNECTION_PWD=
Resolution:
Update to a fix version listed below or a newer version if available.
 

Fix Status: Released

Fix Version(s):
Component(s): Agent PeopleSoft

Automation Engine 12.1.1 - Available
Automation Engine 12.0.4 - Available
Additional Information:
Workaround :
Change the entry in the ini file from domain_Connection_Pwd= to DOMAIN_CONNECTION_PWD=