PDT0144 DETECTOR COLLECTION TIME LIMIT EXPIRED DB2=DB2P

Document ID : KB000074049
Last Modified Date : 11/05/2018
Show Technical Document Details
Question:
User issues this modify command and expect one output file for 10 minutes but get 2 files of 5 minutes. START(DTR)DYN(Y)SDE(Y)CHV(Y)SCA(Y)SQT(Y)SQLT(Y)PRF(DB2PPROF)DB2(DB2P) INT(0010)RND(Y)PLEXINTV(N)EXT(Y)DST(HIST04)HLVL(DBA.PKS.CA.DB2P) DUR(0010)AUTO(N)POOL(2000)TRG(Y)KEYS(Y)
Why is that?
Answer:
User's collection started at 7:45 and the first interval ends at 7:50 because of the round up RND(Y) option. At 7:55 the following message PDT0144 DETECTOR COLLECTION TIME LIMIT EXPIRED DB2=DB2P is displayed because of the 10 minutes specified for interval time (INT).

Here is how the  RND(Y/N) round interval keyword works. Specify one of the following operands to indicate whether to end the collection interval on a time boundary that is an integral multiple of the interval time. This option applies only when specifying an Interval Time;