Parameter retrieves old value during deployment - Release Automation

Document ID : KB000107050
Last Modified Date : 18/07/2018
Show Technical Document Details
Issue:
At both the component and process levels, the internal scoped parameter is set to the correct value. But when the deployment/process executes, the parameter instead uses the old value.
Resolution:
After making any changes to internal scoped parameters, you will need to republish all processes that use the parameter that was changed before the process will use the new value.