OPS/MVS AOF SETAUTO/RESETAUTO receive return code '1' at startup

Document ID : KB000126199
Last Modified Date : 11/02/2019
Show Technical Document Details
Issue:
When performing ADDRESS AOF SETAUTO or RESETAUTO, each command receives a return code of '1' after the upgrade to CA OPS/MVS 13.5. Under previous releases the return code was '0'. 

OPF1098I *-* 2:address aof                     
OPF1098I >L>   AOF                             
OPF1098I *-* 3:'SETAUTO CUSTOM.TESTRUL'        
OPF1098I >L>   SETAUTO CUSTOM.TESTRUL          
OPF4320H OPSD5MN  OPSF *LOCAL* AOF verb SETAUTO
OPF1098I +++    RC(1)                          

Despite the RC=1 the command works normally.
Resolution:
Permanent solution is the PTF SO07289:

https://support.ca.com/us/download-center/solution-detail.html?aparNo=SO07289&os=OS

Workaround:
Set the new OPS/MVS parameter, INITADMINUI, to NO in your OPSSPA00. This will cause the Return Code from the ADDRESS AOF command in the AOFINITREXX to be correct.