OLQ 098002 No record found using concatenated key

Document ID : KB000006111
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

Unexpected message “OLQ 098002 No record found” when retrieving data in OLQ with a concatenated calc or index key.

Environment:
CA-IDMS, OLQ, any supported release.
Cause:

The cause is the IDD DICTIONARY OPTION, "DECIMAL-POINT IS COMMA".

Resolution:

Change the DICTIONARY OPTION to DECIMAL-POINT IS PERIOD or ensure that there is always at least one space after the comma or period (full stop) which is acting as a separator.

If you are using DECIMAL-POINT IS PERIOD or there is at least one space after the separator, there is no problem.

If you are using DECIMAL-POINT IS COMMA and there is no space after the separator, you get the 098002  message.

See the attached text file oq098002.txt for specific examples.

Additional Information:

For more information, see the following CA IDMS DocOps page:

About SET OPTIONS

File Attachments: