Issue:

This document shows a workaround for an issue, where the OIDs are not automatically being updated in the MIB Trap Browser after importing the MIB through the MIB Setup Wizard.

Resolution:

1. Navigate to Nimsoft\MIBS on the server where snmptd is installed. 
2. Copy the MIB.txt file extracted from the device into the MIBS folder.  For more information on how to generate the MIB.txt file from the device please use the following guide:

How to use sapwalk to get a mib dump file


3. After importing the MIB, cold start the snmptd probe through deactivate/activate for the MIB to automatically take effect and the OIDs to be retrieved. 
4. Verify that the OIDS have now been added in the MIB Trap Browser