ntevl probe executing command fails

Document ID : KB000107707
Last Modified Date : 24/07/2018
Show Technical Document Details
Issue:
In this case customer wants to execute following shutdown command on a match
shutdown.exe /r /t 0

but command was not executed and ntevl.log shows:
.. ntevl: mysystem - failed to start: 'cmd /c shutdown /r /t 0 '
... ntevl: failed to execute [cmd /c shutdown /r /t 0 ] error was []

run command on match was turned on and command Executable was:
C:\Windows\System32\shutdown.exe /r /t 0
wrong command

 
Environment:
UIM 8.5.1
NTEVL probe version 4.24  
Cause:
Parameter is not correctly passed when being specified on the command line.
Resolution:
Resolution is to specify the command parameter in the command arguments field instead of appending them in the command.
Specify as :
command executable: C:\Windows\System32\shutdown.exe
command arguments: /r /t 0
working sample