Issue:

 When accessing CEM Analysis Graph, the browser returns this error:

"HTTP ERROR 500

Problem accessing /wily/cem/tess/app/biz/defectReport.html. Reason:

Could not initialize class sun.awt.X11GraphicsEnvironment"

Environment:
Introscope from 9.7 onward.
Cause:

 Sun/Oracle Solaris has a option to tell if the code is running in Headless mode, and avoid using GUI components if having no display.

 The setting is telling it not to expect any GUI.

Resolution:

 To resolve the issue, set- Djava.awt.headless to true inside your JVM arguments.

 If using EMService.conf (running as a service), add the row "wrapper.java.additional.1=-Djava.awt.headless=true"

 If using IntroscopeEnterpriseManager.lax file, add or change to true at the end of JVM arguments "-Djava.awt.headless=true".