Not calculate the number of output paths after copying

Document ID : KB000006084
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

Copy blocks with multi paths.

Past to another flow chart, and then the number of output will be reset despite paths are already connected.

Environment:
This problem was reported on Agile Requirements Designer (ARD) 2.3.000.9
Cause:

This behavior is known problem.

Resolution:

This problem will be fixed on ARD 2.4.
If you need the solution before ARDĀ 2.4 will beĀ released, please contact CA Support.

Additional Information:

Agile Requirements Designer was called Test Case Optimizer (TCO).