Issue:
Error Message :
N/A

Patch level detected:Univiewer Console 4.0.10
Deploying a node settings package for an engine's state at the company startup that has been created with only one engine to "No" and the others to "Yes", all engine on the target node's area go to "No".
Not only the one that was set to "No" on the original node but all the engines will be modified..
Environment:
OS: All
OS Version: ALL
Cause:
Cause type:
Defect
Root Cause: The problem was that the value was not saved in the package
Resolution:
Update to a fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Univiewer Console 4.0.11 - Available
Additional Information:
Workaround :
Manually define "Startup and Shutdown" settings on the target node via UVC or modifying the values.xml