No output is generated when running autosys command in ECLI

Document ID : KB000004838
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

When executing an Autosys command thru ECLI (Enterprise Command Line Interface), no output is being shown in the 'Output' section nor in the 'Errors' section.

Environment:
WCC 11.3.6, WCC 11.4 & Autosys 11.3.x on Unix/Linux platform
Cause:

ECLI communicates to Autosys using the Command Sponsor binaries. Command from WCC is being passed thru iGateway to the Command Sponsor binaries who builds environment to execute the autosys command. It will check the file 'instance2script.map' to see if instance and it's script path is defined.

Also it requires an entry that will execute the autosys command also called AutosysCommandWrapper. This line was missing in instance2script.map file.

Resolution:

On the Autosys box, run following steps:

1. cd $IGW_LOC

2. edit file 'instance2script.map

3. add following line

ASCMDWRP     /opt/CA/SharedComponents/iTechnology/AutoSysCommandWrapper.exe