Issue:
When we enable NCM debug by modifying debug parameter in $SPECROOT/NCM/config.xml, potentially the debug output contains clear text device password. This article describes solution to avoid this issue.
Environment:
All Spectrum versions on all platforms
Resolution:
Currently we have PTF patch that will prevent this problem for Spectrum 10.2.2.
On Spectrum 10.2.2 the issue is addressed by applying PTF_10.2.218a.
Please contact Technical Support to download the PTF file.
Additional Information:
https://docops.ca.com/ca-spectrum/10-2-3/en/managing-network/network-configuration-manager