Multiple S0E0 abends ZOS Agent

Document ID : KB000102372
Last Modified Date : 16/07/2018
Show Technical Document Details
Issue:
-The system message S0E0 Reason 28 
Reserved bit positions in an access list entry token (ALET) were nonzero 

-The offset where the program UCXJM25 aborted 
PSW AT TIME OF ERROR 078C4400 800C1526 ILC 6 INTC 28 
ACTIVE LOAD MODULE ADDRESS=00007000 OFFSET=000BA526 
NAME=UCXJM25 
DATA AT PSW 000C1520 - D207B030 41685850 41041F66 
AR/GR 0: 00000000/00000000 1: 00000000/00006278 
2: FFFFFFFF/00000433 3: FFFFFFFF/000004FA 
4: 00620003/007F509C 5: 00620003/00000000 
6: 00620003/59CD10C7 7: FFFFFFFF/00F18700 
8: FFFFFFFF/03D9A000 9: FFFFFFFF/0000628C 
A: FFFFFFFF/00006248 B: FFFFFFFF/3B682AB8 
C: 00000000/000C1238 D: 00000000/3B682B00 
E: 00000000/00006288 F: 00000000/00000000 
END OF SYMPTOM DUMP 

--

INTERRUPT OCCURRED AT ADDRESS 800C1520 
LAST KNOWN I/O OR CALL OCCURRED AT ADDRESS 00B3B0F0 AT OFFSET +0000F0 IN MODULE CASESSIS 
THE Z/OS BREAKING EVENT ADDRESS IS 00000000 01611912 IN UNKNOWN PROGRAM 

--
 
There may be an issue when trying to write within the CAIPRINT repository, please check the following to confirm:

https://support.ca.com/us/knowledge-base-articles.TEC1754252.html 

The system abend of the started tasks is most probably a side effect (OEO reason 28) — this may not fix the issue. 

3. ACTUAL: The Agent will activate the extended console, it ACTIVATES an extended console, it say successful, but a second later, when the Agent “inactivates” the event console the agent dies. 
The OS390 agent is using access registers without initializing them. We run with a list for DIAG traps successed by IBM to catch coding errors and need this corrected so we can pass out this agent to our systems. 
EXPECTED: The Agent stays active 
This console is only open if the 'defultJobClass' is not set wihin the INIfile of the agent. 

Just set within the '(WLM)' section this parameter: 
f.ex.: 
(WLM) 
defultJobClass=C 
If this is set the function is scipped ($d intrdr,c) – this did not resolve the issue. 
Environment:
For this error, the following information is useful:

Capture of the abend 
JES log
Agent log
Agent trace (TCP/IP=9)
Resolution:
Workaround:None available.

Resolution: Update to at least 12.0.2 Automation Engine/Components, but the latest release of 12.0.x or 12.2.x is recommended. 
Additional Information: