Message ASMA017W when assemling TPXULOGW

Document ID : KB000125382
Last Modified Date : 29/01/2019
Show Technical Document Details
Issue:
Assembling TPXULOGW Exit, the job returns RC=04 because of the following message:

** ASMA017W Undefined keyword parameter; default to positional, including keyword - SMRT /DSECT
 
Environment:
CA-TPX 5.4
Cause:
The member TPXULOGW on TPX.R54.CB0VSRC was not updated from the previous release even if the macro has been changed.
Resolution:
The statement "SMRT DSECT=YES" is incorrect. It should read as "SMRT TYPE=YES" or just "SMRT", since the default value for TYPE is DSECT.
This could be manually changed until the official solution will be available.