Issue:
Error Message :
Warning in the MGRLOG file:

####
LPtrVerif - OSocketArray_Construct2 - pipe() failed errno=124. OSocketArray.c 149
LPtrVerif - OSockComm_Construct2 - OSocketArray_Construct2() failed. OSockComm.c 118
####

You can find in the the following messages in the universe.log:
####
|2014-11-15|00:09:09|WARN |X|ZOS|pid=67109246.467946240|o_zos_run_purge_old_cnx_t|Warning: Closing the connection is delayed, because the connection is still used by DUAS, this could mean that network is slow
####

Patch level detected:Manager for MVS 6.2.41
Product Version: Dollar.Universe 6.2.41

Description :Manager for z/OS cannot submit new job, you can observe in the MGRLOG warning messages.

On the MVS side, the result of netstat command will return a lot of close wait connection states.
Environment:
OS: MVS
Cause:
Cause type:
Defect
Root Cause: Manager for z/OS can no longer process jobs as it does not release TCP sockets
Resolution:
Please keep in mind that to use this manager MVS 6.3.41, you need to use the 6.3.41 versions for Dollar Universe, Univiewer Console and the Univiewer Management Server too (please refer to compatibility Matrix for more details).

When the upgrade is complete, please adjust the value of the variable ZOS_NB_RETRY_FREE_CNX that is used for number of attempts before forcing the connection to be freed

Fix Status: Released

Fix Version(s):
Component: Manager.for.ZOS
Version: Dollar.Universe 6.3.41
Additional Information:
Workaround :
N/A