Issue:
Error Message :
N/A

In Automic's Web Interface (AWI), the select box for the Login Object is greyed out within the VMS Jobs 'Attributes' Tab, so the field can not be accessed.
Environment:
OS Version: N/A
Cause:
Cause type:
Defect
Root Cause: The Login field that allows users to select a Login object when defining VMS, BS2000 or GCOS8 Job objects is not accessible nor editable.
Resolution:
Update to a fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Automic Web Interface 12.1.0 - Available
Automic Web Interface 12.0.2 - Available
Additional Information:
Workaround :
Use the Java UserInterface where the login field is accessible.