Librarian CCF under CA-Roscoe will not work if the LMP expiring message CAS9182A is issued.

Document ID : KB000055038
Last Modified Date : 14/02/2018
Show Technical Document Details

Description:

CCF under CA-Roscoe will receive the following messages if the LMP keys for Librarian are about to expire:

> PNL04 PANEL VARIABLE UNAVAILABLE <CCF.$CHGP001 000050>                     
>                                                                             
....+....1....+....2....+....3....+....4....+....5....+....6....+....7....+...
CAS9182A - WARNING: LMP key Prod (LJ) CA-LIBRARIAN         expires in xxx days
CAS9182A - WARNING: LMP key Prod (LJ) CA-LIBRARIAN         expires in xxx days

Solution:

The CAS9182A message is issued by CAS9 as a Write-to-Programmer (WTP) message and this is causing the current CA-Roscoe panel to become de-activated and hence the panel variables are no longer available.

The customer should arrange to have the LMP keys re-issued as soon as possible.  In order to continue to use CCF under CA-Roscoe the following command can be used before entering CCF:

DIVERT WTP CONSOLE

This will divert all WTP messages to the system console and allow the panel to remain active.  This command will have to be issued at the beginning of new sessions until the LMP keys have been updated.