Jobs restarted using RESTART_UC_OBJECT don't indicate that they've been restarted.

Document ID : KB000084965
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
Error Message :
N/A

Jobs restarted with RESTART_UC_OBJECT don't indicate that they've been restarted. The initial job does not indicate that it was restarted but the restart indicates it was a restart. Neither the icon nor the database fields, ah_restart and eh_restart, are updated. If a job is restarted more than once, the initial job indicates that it was restarted, but the 2nd job does not indicate it was restarted. 

If the Job is manually restarted via the User Interface (UI), then the db values and the icon are correctly updated. Also, in v9, if a restart is performed using the RESTART_UC_OBJECT function, the icon and the database indicate that the job has been restarted. 
Cause:
Cause type:
Defect
Root Cause: Jobs that are restarted using RESTART_UC_OBJECT don't indicate that they have been restarted. If the job is restarted manually it functions correctly.
Resolution:
Update to a fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Automation Engine 11.2.5 - Available
Additional Information:
Workaround :
Restart jobs manually.