Jobs abort without job log when executed in a remote DQM queue

Document ID : KB000086609
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
Error Message :
Error in universe.log on Physical Q server:
Patch level detected:Dollar Universe 6.1.00
Product Version: Dollar.Universe 6.1.0

Description :When using remote physical DQM queues that process an important number of jobs, status and log information does not arrive at the logical queue and jobs abort.
Environment:
OS: All
Related configuration item(s): Logical queue: Linux
Cause:
Cause type:
Defect
Root Cause: This defect is related to the fact that the internal number of a job was not unique when using several DQM queues
Resolution:
Update to the fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Component: Application.Server
Version: Dollar.Universe 6.2.41
Additional Information:
Workaround :