Jobs Abort at startup of the node

Document ID : KB000084791
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
Error Message :
|ERROR|X|IO |pid=p.t| u_io_launch_engines | Unable to check DQM start before starting LAN in area X
...
|ERROR|X|IO |pid=p.t| owls_connect_auth | k_connect_auth_timeout(nodename/DQM) returns error [200]
|ERROR|X|IO |pid=p.t| o_callsrv_connect_r | Connection error 111 [Errno syserror 111: Connection refused]

Upon startup of the node, the engine Launcher started before DQM so several scheduled Jobs Aborted right Away with the "Could not Submit" error as DQM was not present.
Environment:
OS: All
Cause:
Cause type:
Defect
Root Cause: Timing issue, DQM should start before Launcher
Resolution:
Update to a fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Component: Application.Server
Dollar Universe 6.9.01 - Available
Additional Information:
Workaround :
Relaunching the Aborted Jobs or Disabling the automatic startup of the Launcher.