Is there any way to acknowledge and/or close all Autosys alarms at once rather than having to do so one by one via the Alarm Manager?

Document ID : KB000053567
Last Modified Date : 14/02/2018
Show Technical Document Details

Description

The AutoSys GUI requires alarms to be acknowledged or closed one by one via the Alarm Manager. Use these instructions to manually acknowledge and close multiple alarms.

Solution

Run the appropriate sql in the AutoSys DB.

  1. Change all 'open' alarms to 'acknowledged':
    update alarm set state=44 where state=43;


  • Change all 'open' alarms to 'closed':
    update alarm set state=45 where state=43;


  • Change all 'acknowledged' alarms to 'closed':
    update alarm set state=45 where state=44;