Is it possible to change the threshold values of SPM Tests that are discovered as Read-Only?

Document ID : KB000093197
Last Modified Date : 27/04/2018
Show Technical Document Details
Question:
Is it possible to change the threshold values of Service Performance Manager (SPM) Tests that are discovered as Read-Only?
 
Environment:
Spectrum 10.0.x
Spectrum 10.1.x
Spectrum 10.2.x
 
Answer:
Yes, even on Read-Only discovered SPM tests you can change the threshold values for alarming in Spectrum as the thresholds are not part of the test and are used as criteria for Spectrum to create an event or alarm.
To change the threshold of a SPM test you can go to Locater, SPM, All Tests and selected one of the tests that was discovered as Read-Only.  You can then edit the test by selecting the 4th icon from the left (the clock with the pencil icon) and then by clicking the thresholds tab and change whatever threshold you would like.