Insight Batch Report abends.

Document ID : KB000044410
Last Modified Date : 14/02/2018
Show Technical Document Details

Issue/Problem/Symptoms: 

 

Insight Batch report job is abending sometimes with the following message:  

DBG70050W      13:49:08 The following IFCID 2 was processed alone w/o the missing IFCID 1:                                      

DBG70043I      13:49:08 SID 5731, SSID PR2A, SMF time and date 08:00:00.87 2016-06-03, hex 002BF2570116155F                     

DBG11017I      13:51:15 ESTAE EXIT IN NBRWDRV  INVOKED BY ABEND                                                                 

ABEND CODE IS 84878000 - EC PSW AT ABEND IS 070C1000 81605366 - PRIMARY MODE, SUPR STATE, 31-BIT MODE, PASID/SASID=02370237, SRB

ILC, INTERRUPT CODE 0002000D - TRANSLATE EXCEP 00000000                                                                         

EYECATCHER POINTED BY R12 - ¢...÷¥ñ.1.°.~¥(.~..¥(..¥|. ..i...h....8 ..di......                                                  

qü}.i...h....                                                                                                                   

OFFSET TO ABEND ADDRESS FROM R12 IS 00000038                                                                                    

  R0  84000000  R1  84878000  R2  00000004  R3  0C00FA72                                                                        

  R4  009F84E8  R5  00000005  R6  00FF4500  R7  00000878                                                                        

  R8  00000010  R9  19A37360  R10 1F9167F0  R11 000000FA                                                                        

  R12 8160532E  R13 7FF17008  R14 8001EEEE  R15 00000010                                                                        

 AR0  009F84E8 AR1  00000000 AR2  00000000 AR3  00000000                                                                        

 AR4  00000000 AR5  00000000 AR6  00000000 AR7  00000000                                                                        

 AR8  00000000 AR9  00000000 AR10 00000000 AR11 00000000                                                                        

 AR12 00000000 AR13 00000000 AR14 00000000 AR15 00000000                                                                        

DBG98003I      13:51:15  ROUTINES USED    854416 BYTES OF GETMAIN STORAGE

 

 It appears to be related to the volume or content of the SMF records selected for input.

Resolution/Workaround:

 

This is a summary report with GROUP BY THD-START. THD-START is  almost unique to each thread, so naturally the summary request will require a lot of storage. Removing THD-START will most likely solve their problem, but the results will have no resolution in the time domain. To see see everything you should be using TRACE not summarize report. 

 

 

 

 

U

 

 

 

Removing THD-START will most likely solve their problem, but the results will have no resolution in the time domain...