IMS Tran Code is generated wrong

Document ID : KB000097764
Last Modified Date : 23/05/2018
Show Technical Document Details
Introduction:
IMS Tran Code generated incorrectly
Question:
In the Telon Generator step, we are getting the Warning message of;
TLMIMS11 TRANCDE DEFAULTED TO GR315001.  

It appears we are taking a default Tran Code, of the 8 position program name..
The TRANCDE should have been GR315A.
All of our IMS Tran Codes are 6-positions. 
Environment:
Telon Design Facility 
Answer:
They indicated that the TRANCDE should have been GR315A. This could be causing the IMS online transaction error or U0555. They edited the source to change the name to 6 positions, and the transaction ran fine. This change needs to be made in the Telon Design Facility, and then re-genned, recompiled, and re-linked.
Additional Information:
This change can be made with the following steps.
1. From the UPDATE SCREEN DEFINITION, update the ENV IMS

TRCIDA.SD UPDATE SCREEN DEFINITION ** **************** TSO/IMS SCREEN ENV SAVED
COMMAND ==> ___________________________________________________________________
OPTIONS ==> CUSTOM CODE _  DATA GROUP _  PANEL DEF _ ENV IMS    _ SCRN PARMS _

2. In the Update ENV IMS panel; update the TRANCDE

TRCIDA.SD UPDATE TSO/IMS SCREEN ENV * ****************************
COMMAND ==> ______________________________________________________
                                                                  
  IMS:   LINKOPT D (D/S)    CONVERS Y (Y/N)    LINEOPT _ (1/2/3)  
   *     TRACE   _ (Y/N)    PGM/PSB NAME ________                 
   *     GENPCBS Y (Y/N)    LNKCOPY ________   USGCOPY ________   
  TSO:   GENPCBS _ (Y/N)    LNKCOPY ________   USGCOPY ________   
 TRAN:   TRANCDE TRIMCIDA__ TRANMFS Y (Y/N)    TRANFLD ________   
 
  • TRANCDE