IEFTMS78 WARNING: CA 1 TMC EXTEND INDICATOR IS ON

Document ID : KB000094866
Last Modified Date : 07/05/2018
Show Technical Document Details
Issue:
Ran job TMSXTEND with  PARM=TEST and job abended.
Now receiving warning message "IEFTMS78 WARNING: CA 1 TMC EXTEND INDICATOR IS ON" on the CA1 Primary Option Panel
 
Resolution:
Run TMSXTEND with PARM='RECOVER' to recover from abends.
When TMSXTEND runs, it turns on multiple flag bits in Control Record #4 (TMSCTL#4) in the audit file.
Some of these bits indicate the systems that were active at the time TMSXTEND was run, and whether TMSRINIT was run on those systems.

NOTE: Running TMSXTEND with PARM='TEST' will also turn these flag bits on, so if a test run did not complete successfully, the flag bits could be left on.
 
OR
 
Manually update Control Record CTL4 to turn off the flag bits using the program TMSUDSNB.
You will need to use the following control statements:
PASSWORD=yourmasterpassword <<<< change
CTL4 NOVER
REP AUDFLG=00