'IEE296I xxxxxxxx FAILED BY SECURITY INTERFACE. RC= 28' Received During A Started Task Start Up

Document ID : KB000054275
Last Modified Date : 14/02/2018
Show Technical Document Details

Description

  'IEE296I xxxxxxxx FAILED BY SECURITY INTERFACE. RC= 28' 

Received during a Started Task Start Up.

Solution

Is Started Task acid suspended?

If yes, remove the suspension with a:

  TSS REMOVE(startedtaskacid) SUSPEND.

If no, please check the following:

  1. Check that the Started task is defined to the STC table via:
      TSS LIST(STC)
    and search for the procname. Also confirm that the Started Task has an ACID specified in the STC table.

  2. Does the Started Task have FAC(STC)? Issue a:
      TSS LIST(startedtaskacid) 
    to determine this. If it doesn't, issue a:
      TSS ADD(startedtaskacid) FAC(STC).

Please refer to the CA Top Secret Command Functions Guide for more details about the TSS LIST and TSS REMOVE command.

Please refer to the CA Top Secret BATCH, STC and APPC Guide for more details about Started Tasks.