IEA705I ERROR DURING GETMAIN SYS CODE = 878-10

Document ID : KB000008634
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

A003 error + S878 Abend in CA Easytrieve 6.4 or a similar error in release 11.n:

...

*******A003 INSUFFICIENT CORE STORAGE AVAILABLE - 00 00170A88 D020 0538 

...

IEA705I ERROR DURING GETMAIN SYS CODE = 878-10 CCC1234 STEPABC MATCH 00

IEA705I 00FBD580 009F8030 009F8030 00005200 0000DAB8                   

IEA995I SYMPTOM DUMP OUTPUT  800                                       

SYSTEM COMPLETION CODE=878  REASON CODE=00000010                       

 TIME=17.40.57  SEQ=05583  CPU=4000  ASID=0070                         

 PSW AT TIME OF ERROR  470C1000   815EE260  ILC 2  INTC 0D             

   NO ACTIVE MODULE FOUND                                              

   NAME=UNKNOWN                                                        

...

You could also see something like this:

...

USED PRIVATE AREA ABOVE 16MB:              0M

...

in the job output.

Resolution:

The reason is likely that ALL31 is set to OFF (the default) in the CA Easytrieve 6.4 Options Table.

In this case the problem can be resolved by changing ALL31 to ON.

For release 11.6 see AMODE31 option, please:

https://docops.ca.com/ca-easytrieve/11-6/en/configuring/configure-your-system/updating-the-table

 

Additional Information:

In order to get more information about options and how to display and change them, see documentation and these technical knowledge documents/articles:

https://support.ca.com/us/knowledge-base-articles.TEC1945118.html  

https://support.ca.com/us/knowledge-base-articles.tec616508.html  

https://support.ca.com/us/knowledge-base-articles.FAQ258145.html