CTS 5.4 Ideal PLT program @IADPLTI has abended, code AEI0.

Document ID : KB000095709
Last Modified Date : 19/10/2018
Show Technical Document Details
Issue:
I applied PTF's RO96679 and RO96515 to Ideal R14 for CICSTS 5.4 compatibility.
When I start the CICS I receive the following.

DFHSI1580D PRODIDDB PLT program @IADPLTI has abended, code AEI0. Reply GO or CANCEL
Environment:
CA Ideal and CA IPC 14.0 and higher
Cause:
New VPE modules named VPEHJE71 and VPEHJN71 to execute in CICS 7.1 for IPC/IDEAL are missing.
Resolution:

IPC APAR #: RO96230   15.1   CTS 5.4 SUPPORT 
IPC APAR #: RO95301   15.0   CTS 5.4 SUPPORT 
IPC APAR #: RO96231   14.0   CTS 5.4 SUPPORT 
Additional Information:
See CICS compatibility Support for all CA Products at:
ftp://ftp.ca.com/pub/MSPSaccount/COMPAT/cics_compat.HTML

Both new VPE modules must be defined execkey=cics.

For Ideal/IPC 15.1 see the following APARs: 
- SO03980 15.1 AEZC ABEND W/CTS 5.4 IN TRANSID IDPI BUILDING LMT 
- SO03797 15.1 D IND MOD VER & REFRESH AEZC ABEND W/CTS 5.4 
- RO96666 15.1 CAT DB2 DVW AEZC IN CTS 5.4 
- RO96124 15.1 DISPLAY PCT GETS AEZC ABEND IN CTS 5.4 
APAR #RO96666 is not needed if you don't have Ideal/DB2. 
The three other APARs are required for Ideal 15.1 under CTS 5.4.