I ran the TQINST EXEC as part of the installation of the VM extension component of Dynam T VSE 7.0, but the process ended with RC=08. How do I determine what is wrong?

Document ID : KB000055345
Last Modified Date : 14/02/2018
Show Technical Document Details

TQINST ends with the following error messages;

=======> DTPARMS ASSEMBLE ERROR, RC=8 
37 *-* exit 999 
=======> ERROR HAS OCCURRED - INSTALL ABORTED

To determine what the error is, edit TQASM EXEC and change line 15 from "address'' atype 'DTPARMS (NOPRINT NODECK OBJECT' "to address'' atype 'DTPARMS (PRINT NODECK OBJECT'

Changing the NOPRINT option to PRINT will allow an assembler listing to be generated which will show any errors encountered during assembly.

A typical assembler error, which might be generated;

STMT ERROR CODE MESSAGE 
ASM 0201 12.02 04/16/07 
    1 IFO091     KEYWORD PARAMETER SECHECK IS DUPLICATED ON SAME 
MACRO CALL 
NUMBER OF STATEMENTS FLAGGED IN THIS ASSEMBLY =    1 
HIGHEST SEVERITY WAS 8