I have two systems, one RACF and the other CA ACF2. I can NJE batch jobs from RACF to ACF2 with no problems, but ACF2 to RACF fails with message: ICH408I

Document ID : KB000026856
Last Modified Date : 14/02/2018
Show Technical Document Details

Problem:

I have two systems, one RACF and the other ACF2.

I have a user defined to both systems with exactly the same userid/password specified.

I can NJE batch jobs from RACF to ACF2 with no problems, but ACF2 to RACF fails with message:

ICH408I USER(userid ) GROUP(groupname ) NAME(user name) SUBMITTER(????????) LOGON/JOB INITIATION - SUBMITTER IS NOT AUTHORIZED BY USER.

 

 

Resolution:

Check your ACF2 NJE parms for this connection. The ENCRYPT parm is only valid for ACF2 to ACF2 systems. Turn that off to a RACF system.

TSO ACF
ACF
SET CONTROL(GSO)
CHANGE NJEqual NOENCRYPT
F ACF2,REFRESH(NJE)
END

You may need to create a separate NJE record for this one system if you are using a masked record being shared by multiple systems.