I am getting error message IEW2635I while attempting to apply an apar in CA ACF2.

Document ID : KB000027395
Last Modified Date : 14/02/2018
Show Technical Document Details

Problem:

While attempting to apply an APAR, the following error message is generated:

IEW2635I 4B34 THREE BYTE ADCON IN SECTION CRLPERSL AT OFFSET 0005526D 
IN CLASS B_TEXT WITH RMODE=ANY CANNOT BE RELOCATED.

 

Resolution:

  • This and similar types of messages (see below) do not necessarily indicate any problems or errors with the APPLY and can be considered normal as long as the APPLY completes with a return code of 4 or less.
  • The following is a description of various SMP/E messages that may be issued during APPLY processing.
  • GIM20501I APPLY PROCESSING IS COMPLETE. THE HIGHEST RETURN CODE WAS 04.

  • IEW2609W 5104 SECTION section-name USABILITY ATTRIBUTE OF REUSABLE CONFLICTS WITH REQUESTED USABILITY OF REENTRANT.

  • IEW2646W 4B07 ESD RMODE(24) CONFLICTS WITH THE USER-SPECIFIED RMODE(ANY) FOR SECTION section-name.

  • IEW2651W 511C ESD AMODE 24 CONFLICTS WITH USER-SPECIFIED AMODE 31 FOR ENTRY POINT entry-name.

  • IEW2454W 9203 SYMBOL symbol-name UNRESOLVED. NO AUTOCALL (NCAL) SPECIFIED.

  • IEW2635I 4B34 THREE BYTE ADCON IN SECTION section-name AT OFFSET offset IN CLASS B_TEXT WITH RMODE=ANY CANNOT BE RELOCATED.

  • IEW2650I MODULE ENTRY NOT PROVIDED. ENTRY DEFAULTS TO SECTION section-name.

  • IEW2745S ABEND abend-code OCCURRED WHILE PROCESSING PARTITIONED DATA SET WITH DDNAME ddname.