How to specify multiple SNAPEXCL= values with AUTOSTAT?

Document ID : KB000093036
Last Modified Date : 04/05/2018
Show Technical Document Details
Question:
How to specify multiple SNAPEXCL= values with AUTOSTAT?

I tried:
.........1.........2.........3.........4.........5.........6.........7..... AUTOSTAT MUFNAME=DBMUFDV,DBID=1018,REPEATS=900,OUTTAG=PRODL1.DBMUFDV, SNAPEXCL=(DURATION0,NOTACTIVE) **** SNAPEXCL=DURATION0, DB10004E - KEYWORD VALUE TOO LONG

I tried:
.........1.........2.........3.........4.........5.........6.........7..... AUTOSTAT MUFNAME=DBMUFDV,DBID=1018,REPEATS=900,OUTTAG=PRODL1.DBMUFDV, SNAPEXCL=DURATION0,NOTACTIVE *** INVALID KEYWORD - NOTACTIV
Environment:
z/os, CA Datacom/DB 14.0 and over 
Answer:
From the AUTOSTAT diagram, you can repeat the parameter SNAPEXCL= with another value.

Reference:
https://docops.ca.com/ca-datacom/15-1/en/reference/dbutlty-reference/utility-function-summary/autostat-report-on-muf-information.